Fiber optic splitter is an integrated wave guide optical power distribution device that can split an incident light beam into two or more light beams, and vice versa, containing multiple input and output ends. An optical splitter plays an important role in passive optical networks (such as EPON, GPON, BPON, FTTX, FTTH, etc.) by allowing a single PON interface to be shared among many subscribers.
The passive optical splitter can split/separate an incident light beam into several light beams at a certain ratio. The 1x4 split configuration presented below is the basic structure: separating an incident light beam from a single input fiber cable into four light beams and transmitting them through four individual output fiber cables. For instance, if the input fiber optic cable carries 1000Mbps bandwidth, each user at the end of output fiber cables can use the networkwith 250 Mbps bandwidth.
PLC (Planar Light Wave Circuit) Splitter is based on planar light wave circuit technology and precision aligning process, can dividea single/dual optical input(s) into multiple optical outputs uniformly and is denoted 1xN or 2xN .PLC Splitter is applied in FTTX deployments, PON networks,CATV links and optical signal distribution currently. GoodFtth's PLC Splitteroffers superior optical performance, high stability and high reliability, meetvarious application requirements in different environments.
Application:
LAN System
CATV System
Testing Equipment
Telecommunication System
Feature:
Low PDL.
Low Insertion loss
Excellentuniformity
Good repeatability
1×N Module PLC Splitter Specification | ||||||||||||
Port Configuration | Ch | 1*2 | 1*4 | 1*8 | 1*16 | 1*32 | 1*64 | |||||
Fiber Type | SMF-28e, G652, G655, G657 (or Customized) | |||||||||||
Operating Wavelength | nm | 1260-1650 | ||||||||||
IL | Typical(dB) | ≤3.9 | ≤7.2 | ≤10.3 | ≤13.6 | ≤16.9 | ≤20.2 | |||||
UL | dB | ≤0.5 | ≤0.6 | ≤0.8 | ≤1.0 | ≤1.3 | ≤1.8 | |||||
PDL | dB | ≤0.3 | ≤0.3 | ≤0.3 | ≤0.3 | ≤0.3 | ≤0.4 | |||||
RL | dB | ≥50 | ||||||||||
Directivity | dB | 55 | ||||||||||
Operating Temperature | ℃ | -40~+85 | ||||||||||
Storage Temperature | ℃ | -40~+85 | ||||||||||
Steel tube size | mm | 40*4*4 | 40*4*4 | 40*4*4 | 50*7*4 | 50*7*4 | 60*12*4 | |||||
ABS Size | mm | 100*80*10 | 100*80*10 | 100*80*10 | 120*80*10 | 120*80*10 | 141*115*18 | |||||
2×N Module PLC Splitter Specification | ||||||||||||
Port Configuration | Ch | 2*2 | 2*4 | 2*8 | 2*16 | 2*32 | 2*64 | |||||
Fiber Type | SMF-28e, G652, G655, G657 (or Customized) | |||||||||||
Operating Wavelength | nm | 1260-1650 | ||||||||||
IL | Typical (dB) | ≤4.0 | ≤7.6 | ≤10.8 | ≤14.1 | ≤17 | ≤20.5 | |||||
UL | dB | ≤1 | ≤1.4 | ≤1.5 | ≤2 | ≤2.5 | ≤2.5 | |||||
PDL | dB | ≤0.2 | ≤0.2 | ≤0.4 | ≤0.4 | ≤0.4 | ≤0.5 | |||||
RL | dB | ≥50 | ||||||||||
Directivity | dB | 55 | ||||||||||
Operating Temperature | ℃ | -40~+85 | ||||||||||
Storage Temperature | ℃ | -40~+85 | ||||||||||
Steel Tube Size | mm | 60*7*4 | 60*7*4 | 60*7*4 | 60*7*4 | 80*20*6 | / | |||||
ABS Size | mm | 100*80*10 | 100*80*10 | 100*80*10 | 120*80*10 | 120*80*10 | 141*115*18 |